Technical Data
108/145
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM36EN | Revision 36 | English | 2012-10 | Released | Public
© Hilscher, 2008-2012
10.1.18 CIFX
70E-DP
Item
CIFX 70E-DP
System Interface
(Bus Type)
PCI Express, One Lane Port, according to [bus spec 2; Rev. 2.0] and [bus spec
3], (refer to section
Overview on the Pin Assignment at the Bus
, page 95,
transmission rate 2 GBit/s, 32-Bit width for the data access to the Dual-Port
Memory (DPM), or IO-DMA (Direct Memory Access)
Dual-Port Memory Size
64 KBytes
Function
Communication interface with PCI Express and PROFIBUS interface
Communication
Determined by the loaded firmware
Protocols
PROFIBUS DP Master, PROFIBUS MPI Device, PROFIBUS DP Slave
Processor
netX 100
LEDs
SYS, COM; (refer also to chapter
LED Descriptions
, page 66.
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Configuration Software
SYCON.net (Master and Slave) or netX Configuration Tool (only Slave)
PROFIBUS Interface
DSub female Connector, 9 pin; Isolated RS-485 Interface;
(refer also to chapter
PROFIBUS Interface
page 88.
Supply Voltage
+3,3 V ±5 %/Typ. 800 mA
Dimensions (L x W x D)
119,0 x 69,0 x 18,5 mm
Operating Temperature
0 °C ... +65 °C
Environment
The device must be used in a pollution degree 2 environment.
UL Certification
The device is UL 508 certified (UL-File No E221530).
Table 104: Technical Data CIFX 70E-DP
10.1.19 CIFX
70E-CO
Item
CIFX 70E-CO
System Interface
(Bus Type)
PCI Express, One Lane Port, according to [bus spec 2; Rev. 2.0] and [bus spec
3], (refer to section
Overview on the Pin Assignment at the Bus
, page 95,
transmission rate 2 GBit/s, 32-Bit width for the data access to the Dual-Port
Memory (DPM), or IO-DMA (Direct Memory Access)
Dual-Port Memory Size
64 KBytes
Function
Communication interface with PCI Express and CANopen interface
Communication
Determined by the loaded firmware
Protocols
CANopen Master, CANopen Slave
Processor
netX 100
LEDs
SYS, CAN; (refer also to chapter
LED Descriptions
, page 66.
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Configuration Software
SYCON.net (Master and Slave) or netX Configuration Tool (only Slave)
CANopen Interface
DSub male Connector, 9 pin; Isolated ISO-11898 Interface;
(refer also to chapter
CANopen Interface
, page 88.
Supply Voltage
+3,3 V ±5 %/Typ. 800 mA
Dimensions (L x W x D)
119,0 x 69,0 x 18,5 mm
Operating Temperature
0 °C ... +65 °C
Environment
The device must be used in a pollution degree 2 environment.
UL Certification
The device is UL 508 certified (UL-File No E221530).
Table 105: Technical Data CIFX 70E-CO