Technical Data
113/145
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM36EN | Revision 36 | English | 2012-10 | Released | Public
© Hilscher, 2008-2012
10.4.3
EtherNet/IP Scanner (Master)
Parameter
Description
Maximum number of EtherNet/IP connections
64 connections for implicit and explicit
Maximum number of total cyclic input data
5712 bytes
Maximum number of total cyclic output data
5760 bytes
Maximum number of cyclic input data
504 bytes per slave per telegram
Maximum number of cyclic output data
504 bytes per slave per telegram
IO Connection type
Cyclic, minimum 1 ms (depending on used number of connections
and used number of input and output data)
Maximum number of unscheduled data
1400 bytes per telegram
UCMM, Class 3
Supported
Explicit Messages, Client and Server Services
Get_Attribute_Single/All
Set_Attribute_Single/All
Predefined standard objects
Identity Object
Message Route Object
Assembly Object
Connection Manager
Ethernet Link Object
TCP/IP Object
Maximal number of user specific objects
20
Topology
Tree, Line, Ring
DLR (Device Level Ring)
Beacon based ’Ring Node’
ACD (Address Conflict Detection)
Supported
DHCP Supported
BOOTP Supported
Baud rates
10 and 100 MBit/s
Data transport layer
Ethernet II, IEEE 802.3
Integrated switch
Supported
Limitations
CIP Sync Services are not implemented
TAGs are not supported
Reference to firmware/stack version
V2.4.x.x
Table 111: Technical Data EtherNet/IP Scanner (Master) Protocol