Technical Data
106/154
PC Cards cifX PC/104 | Installation, Operation and Hardware Description
DOC120206UM42EN | Revision 42 | English | 2014-12 | Released | Public
© Hilscher, 2008-2014
CIFX 104-CO,
CIFX 104-CO-R
Parameter
Value
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool
Table 88: Technical Data CIFX 104-CO, CIFX 104-CO-R
10.1.6 CIFX 104-CO\F, CIFX 104-CO-R\F
CIFX 104-CO\F,
CIFX 104-CO-R\F
Parameter
Value
Name
CIFX 104-CO\F
CIFX 104-CO-R\F
Part No.
1278.501
1279.501
Description
PC Card cifX PC/104 CANopen Master or Slave
composed of:
- Basic card CIFX 104-FB\F or CIFX 104-FB-R\F* with
cable connector Fieldbus X4 (X304) and cable connector
DIAG X3 (X303) (*connectors at the right side)
- CANopen assembly interface (AIFX-CO) and
- diagnostic assembly interface (AIFX-DIAG).
Part
Function
Communication Interface with PC/104 and fieldbus
interface CANopen
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
16 KByte
Bus Type
PC/104, according to [bus spec 8], refer to section
Overview
, page 95.
Transmission Rate
33 MHz
Data Access
DPM
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
8 Bit or 16 Bit
CANopen
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
CANopen Master,
CANopen Slave
Transmission Rate
10 kBit/s, 20 kBit/s, 50 kBit/s, 100 kBit/s, 125 kBit/s,
250 kBit/s, 500 kBit/s, 800 kBit/s, 1 MBit/s
Interface Type
ISO-11898, refer to section
CANopen Interface
, page 89.
CANopen Interface
CANopen Assembly Interface
AIFX-CO, refer to section
AIFX-CO
, page 114.