Hardware Installation and Uninstalling
61/154
PC Cards cifX PC/104 | Installation, Operation and Hardware Description
DOC120206UM42EN | Revision 42 | English | 2014-12 | Released | Public
© Hilscher, 2008-2014
Connect AIFX-DIAG
Only for the basic cards CIFX 104-RE\F and CIFX 104-RE-R\F or the basic
cards CIFX 104-FB\F and CIFX 104-FB-R\F:
8. If so, connect the diagnostic assembly interface (AIFX-DIAG):
Connect the
cable connector DIAG X1
on the diagnostic assembly
interface (AIFX-DIAG) with the cable.
Connect the
cable connector DIAG X3
(or X303) on the PC card cifX
with the cable.
Install the assembly interface AIFX-DIAG at the front plate of the PC
cabinet).
Important!
The contacts on the connection
cable must face up!
Figure 34: Connecting the Diagnostic Assembly Interface (AIFX-DIAG) to the Basic Card
CIFX 104-FB-R\F (Example)
After this:
9. Close cabinet.
Close the cabinet of the PC or connecting device.
10. Plug the connecting cable to the Master or Slave.
For the PC cards CIFX 104-RE\F or CIFX 104-RE-R\F note:
Note:
The RJ45 socket is only for use in LAN, not for telecommuni-cation circuits. For
further information refer to section
Ethernet Interface
on page 87.
Plug the connecting cable from the PC card cifX to the PC card Master
or Slave.
11. Connect the PC or the connecting device to the power supply and
switch it on.
Connect the PC or the connecting device to the power supply.
Switch on the PC or the connecting device.