Description
19/63
3
Description
3.1
Functionality
The netTAP
NT 151-CCIES-RE
is a communication gateway connecting a
CC-Link IE Field network (at X2 interface of the device) to a PROFINET IO
network (at X3 interface of the device). Currently available is the protocol
conversion CC-Link IE Field Slave to PROFINET IO Device.
For handling the network communication, each interface is equipped with
its own CPU: The CC-Link IE Field network (X2) is operated by a
CP520
chip, the PROFINET network (X3) by a
netX 100
controller.
In addition to cyclic process data, the gateway can also exchange acyclic
data.
Figure 1: Data flow netTAP NT 151-CCIES-RE
netTAP NT 151-CCIES-RE | CC-Link IE Field Slave to PROFINET IO-Device gateway
DOC180403UM01EN | Revision 1 | English | 2018-08 | Released | Public
© Hilscher 2018