Technical data
59/63
12.2.2
CC-Link IE Field Slave
Parameter
Description
Station types
Intelligent Device Station
Maximum number of cyclic input
data
RY data: 256 bytes (2048 bits)
RWw data: 716 words (each 16 bit)
Maximum number of cyclic output
data
RX dta: 256 bytes (2048 bits)
RWr data: 720 words (each 16 bit)
Acyclic communication
SLMP: read and write “Message Interface Buffer” and
“User Defined Buffer”
Baud rate
1 GBit/s, full-duplex
Data transport layer
Ethernet II, IEEE 802.3
Reference to firmware / stack
version
V1.3 / V1.1
Table 24: Technical data CC-Link IE Field Slave protocol
12.2.3
Protocol coupler
Category
Parameter
Value
Data buffers cyclic
communication
From PROFINET to CC-Link IE Field (effectively usable data size)
1432 bytes
From CC-Link IE Field to PROFINET (effectively usable data size)
1428 bytes
Data Buffer acyclic
communication
Quantity of Message Interface Buffer from PROFINET to CC-Link IE
Field with "handshake" procedure
1 with 8-buffer-FIFO
Quantity of Message Interface Buffer from CC-Link IE Field to
PROFINET with "handshake" procedure
1 with 8-buffer-FIFO
Quantity of User Defined Buffers without "handshake" procedure
256
Maximum data size per acyclic message (limited by SLMP)
960 bytes
Table 25: Technical data protocol coupler
netTAP NT 151-CCIES-RE | CC-Link IE Field Slave to PROFINET IO-Device gateway
DOC180403UM01EN | Revision 1 | English | 2018-08 | Released | Public