Configuring EtherNet/IP and defining signals
191/263
13.2.1
Project - Save
To save the configuration data in the device, proceed as follows:
Ø
Click
Project
>
Save
.
ð
The configuration will be saved within the Edge Gateway.
13.2.2
EDS Download
The EDS file contains the Ethernet/IP properties of the Edge Gateway and
is required for configuring the Ethernet/IP Scanner. Download the EDS file
from the Edge Gateway in order to use it in the configuration tool of the
Ethernet/IP Scanner.
To download the EDS file, proceed as follows:
Ø
Click
Download
>
EDS
.
A dialog for saving the EDS file will be displayed.
Ø
Select a folder and then click
Save
.
Ø
Use the saved EDS file to configure the EtherNet/IP Scanner.
Edge Gateway | NIOT-E-TIB100-GB-RE (Remote)
DOC170501UM04EN | Revision 4 | English | 2018-08 | Released | Public
© Hilscher 2017 – 2018