Configuring EtherNet/IP and defining signals
187/258
Parameters for setting the IP addresses
Parameter
Description
DHCP
Activate/ deactivate DHCP protocol in order to configure the IP address
via DHCP.
BootP
Activate/ deactivate BootP protocol in order to configure the IP address
via BootP.
Fixed Address
Activate/ deactivate a fixed IP configuration
IP address
Specify the IP address of the Edge Gateway when configuring IP
settings manually.
Network mask
Specify the network mask of the Edge Gateway when configuring IP
settings manually.
Gateway
If necessary, specify the gateway address of the IP gateway here.
Table 59: Parameters for setting the IP addresses
If multiple options have been checked, these are evaluated in the following
sequence:
1. DHCP
2. BOOTP
3. Fixed IP settings
13.3.2
IO and signal configuration
On this page, you configure the send and receive assemblies for EtherNet/
IP within the Edge Gateway. The Edge Gateway works as an EtherNet/IP
Adapter
In the context of EtherNet/IP, an „IO Item“ corresponds to an EtherNet/IP
send or receive assembly.
The upper table (
Available IO items
) displays the list of the possible
(selectable) send and receive assemblies:
·
The Send Assembly (IO item
Send
, Instance ID usually 100) acts as a
producer and transmits data from the application to the network.
·
The Receive Assembly (IO item
Receive
, Instance ID usually 101) acts
as a consumer and transmits data from the network to the application.
At maximum, one send and one receive assembly can be configured.
EtherNet/IP assemblies have a configurable data length: possible lengths
range from 1 up to 504 Byte each for send and receive data (see columns
Min_length
and
Max_length
).
The lower table (
IO items
) displays the EtherNet/IP configuration and is
empty at the beginning.