Fault
Possible cause
Remedy
The cartridge strip cannot be
removed.
The tool is damaged or has over-
heated as a result of an excessively
high fastener driving rate.
Allow the tool to cool.
Subsequently remove the cartridge
strip carefully from the tool.
WARNING
Do not attempt to forcibly remove
cartridges from the magazine strip or
tool.
Contact Hilti.
The tool is damaged.
Contact Hilti.
The cartridge strip melts.
The tool is pressed against the work-
ing surface for too long before firing.
Fire the tool sooner after pressing it
against the working surface.
The fastener driving rate is too high.
Do not exceed the maximum recom-
mended fastener driving rate.
Remove the cartridges.
Dismantle the tool to allow quicker
cooling and to avoid possible dam-
age.
A cartridge detaches itself from
the cartridge strip.
The fastener driving rate is too high.
Stop using the tool immediately.
Remove the cartridge strip.
Allow the tool to cool down.
Clean the tool and remove any loose
cartridges.
WARNING
Do not attempt to forcibly remove
cartridges from the magazine strip or
tool.
Fastener driving depth varies.
The tool is fouled with dirt and
residues.
Clean the tool.
en
24
Printed: 17.04.2014 | Doc-Nr: PUB / 5069829 / 000 / 03
Summary of Contents for DX 351-CT
Page 2: ...1 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 3: ...2 3 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 4: ...4 5 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 5: ...6 7 8 9 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 6: ...10 11 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...