Declared measured values of noise characteristics according to 2006/42/EC Machinery Directive in conjunction
with DIN EN 15895
Noise (power) level, L
WA, 1S
1
110 dB (A)
Emission noise-pressure level in the work station,
L
pA, 1s
2
97 dB (A)
Peak sound pressure emission level, L
pC, peak
3
127 dB (C)
1 ± 2 dB (A)
2 ± 2 dB (A)
3 ± 2 dB (C)
Operation and set-up conditions:
Set-up and operation of the pin driver in accordance with E DIN EN 15895-1 in the
semi-anechoic test room of Müller-BBM GmbH. The ambient conditions in the test room conform to DIN EN ISO 3745.
Testing procedure:
Enveloping surface method in anechoic room on reflective surface area in accordance with
E DIN EN 15895, DIN EN ISO 3745 and DIN EN ISO 11201.
NOTE The noise emissions measured and the associated measurement uncertainty represent the upper limit for the
noise values to be expected during the measurements.
Variations in operating conditions may cause deviations from these emission values.
14.2 Vibration
Total vibration in accordance with 2006/42/EC does not
exceed 2.5 m/s².
Further information about user health and safety can be
found at www.hilti.com/hse.
en
28
Printed: 17.04.2014 | Doc-Nr: PUB / 5069829 / 000 / 03
Summary of Contents for DX 351-CT
Page 2: ...1 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 3: ...2 3 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 4: ...4 5 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 5: ...6 7 8 9 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...
Page 6: ...10 11 Printed 17 04 2014 Doc Nr PUB 5069829 000 03 ...