*2194029*
2194029
English
13
Result 2 / 3
• Nail stand-off is too high.
▶
Increase the power setting by turning the power
regulation wheel to the next higher setting.
Result 3 / 3
• Nail stand-off is too low.
▶
Reduce the power setting by turning the power
regulation wheel to the next lower setting.
2. Drive another fastener.
3. Repeat the previously described steps until the correct nail stand-off is achieved.
6.3
Adjusting the power setting
@
Power regulation wheel
;
Power setting indicator
▶
Turn the power regulation wheel to set the desired
nail driving power.
▶
The current power setting is indicated.
6.4
Removing cartridges from the tool
1. Press the cartridge strips forward, as far as possible, in the direction of advance.
2. Pull the cartridge strips out of the tool at the cartridge strip exit aperture.
6.5
Removing fasteners from the tool
The fasteners can normally remain in the tool. It is not necessary to remove them, for example, when
you are finished working with the tool.
1. Check that the cartridges have already been removed from the tool. → page 13
2. Stand the tool on its grip.
3. Use the ramrod
(1)
supplied, or an equivalent tool, to push the fasteners back into the magazine.
4. Press the red latch at the mouth of the magazine and allow the fastener strips to slide back out of the
magazine.
7
Care and maintenance
7.1
Check the piston and piston brake and replace the parts if necessary.
The condition of the piston and piston brake must be checked at regular intervals and at least daily.
1. Disassemble the base plate. → page 14
2. Pull out the catch and hold it in this position. Pull the piston out of the piston guide and then release the
catch.
Summary of Contents for DX 9-HSN
Page 1: ...DX 9 HSN English 1 Français 20 Español 40 ...
Page 2: ...1 ...
Page 3: ...2 3 4 5 ...
Page 4: ...6 7 8 9 ...
Page 5: ...10 11 12 ...
Page 6: ...13 ...
Page 8: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ...Hilti registered trademark of Hilti Corp Schaan Pos 3 20220503 2194029 2194029 ...