b)
Do not allow the batteries to overheat and do not
expose them to fire.
The batteries may explode or
release toxic substances.
c)
Do not charge the batteries.
d)
Do not solder the batteries into the tool.
e)
Do not discharge the batteries by short circuiting
as this may cause them to overheat and present
a risk of personal injury (burns).
f)
Do not attempt to open the batteries and do not
subject them to excessive mechanical stress.
6 Before use
NOTE
The tool may be powered only by the PPA 82 battery or
by batteries manufactured in accordance with IEC 285.
NOTE
Do not use damaged batteries, do not mix old and new
batteries and do not mix batteries from various manufac-
turers or batteries with different type designations.
6.1 Switching the tool on
Press the ON / OFF button.
NOTE
The PP 10/25 is capable of leveling itself within a range
of +/- 10%. The tool levels itself automatically when set
up within this range. The LED begins to blink when the
inclination of the tool is more than +/- 10% from the
set inclination. The tool should then be rotated in the
direction indicated by the arrow.
6.2 Battery warning indicator
3
@
Adequate voltage
The tool can be used.
;
Low voltage
The tool can still be used.
=
The battery is discharged.
Charge the NiMH battery or insert new alkaline batteries.
%
The display blinks
The PPA 84 12V connecting cable is used for charging the laser tool.
6.3 Removing the PPA 83 battery holder or PPA 82
battery
1. Turn the battery compartment lockbutton to “OPEN”
and remove the battery box or battery pack.
6.4 Replacing the batteries in the PPA 83 battery
box
1. The battery compartment in the PPA 83 battery box
can also be opened. To do this, turn the lockbutton
on the battery compartment cover to the “OPEN”
position.
2. Replace the used batteries in the battery box with
new ones.
6.5 Fitting the PPA 83 battery holder or PPA 82
battery
1. Reinsert the battery box or battery pack.
2. Turn the lockbutton to the “LOCK” position.
6.6 Connecting the PPA 84 cable
NOTE
If using a battery fitted to a motor vehicle, please first
switch off the engine.
NOTE
Take care to ensure correct polarity when connecting
both terminals.
NOTE
Switch the tool off before connecting or disconnecting
the external power cable.
The connecting cable is designed for connecting to a 12
V battery.
1. Connect the red clip to the positive (+) pole.
2. Connect the black clip to the negative (-) pole.
6.7 Charging the PPA 82 battery
Charging should take place in a room where the temper-
ature is b10ºC and +40ºC.
The battery is charged automatically when the laser is
operated at a temperature of [+10ºC to +40ºC] with an
external battery.
1. Fit the PPA 81 charging adapter to the PPA 82
battery.
2. Connect the power supply unit to the charging ad-
apter.
3. Plug the power supply unit into a power outlet.
4. Check that the correct voltage has been set on the
power supply unit.
The charging control lamp lights green when the
charging operation is complete.
en
19