16
◁
The ± indicator blinks.
3. Press the direction buttons in order to reach the correct position.
4. Press the up / down buttons to change the value.
5. Press the Set button when the value entered is correct.
◁
The laser beam begins to move to the specified setting.
5.7 Aligning the target line
▶
Use the direction buttons to move the laser beam horizontally to the right or left.
Note
The tool itself or the remote control unit can be used to align the target line.
5.8 Setting the beam position
1. Press the button briefly to move the laser beam slowly.
2. Press the button for longer to move the laser beam more quickly.
3. The display begins to blink when the laser reaches the farthest right or left position. If this position is
reached frequently it is recommended that the tool is pivoted slightly to the left or right and the beam
then realigned.
5.9 Automatic centering
▶
Press both direction control buttons at the same time.
◁
The laser beam returns to the center automatically.
5.10 Automatic alignment with the target plate
1. Set up the target plate with the reflective strips facing the laser tool.
2. Press the target plate auto-centering button.
◁
This function may take up to 2 minutes to start.
◁
The tool then searches for the target plate within its alignment range (right/left).
5.11 Selecting the laser beam mode
1. Press the laser beam mode button as often as necessary until the desired operating mode is shown in
the display.
2. Select the desired operating mode:
◁
Constant beam
◁
Blinking beam
5.12 Adjusting the electronic bubble level
1. The bubble level appears in the display when the tool is turned.
2. Level the tool until the “bubble” is centered in the display.
◁
The LED begins to blink as soon as the tool’s compensation range is exceeded.
5.13 Fitting the screw feet and centering screw
▶
Fit the appropriate feet for the pipe diameter before setting up the laser in the pipe.
5.14 Setting the target plate size
▶
Set the target plate size in accordance with the diameter of the pipe.
5.15 Setting the % or ‰ unit of measure
1. Press the on / off button and the lock button at the same time.
2. Use the up / down buttons to move to the “Unit” line.
3. Press the direction button to select the value you wish to change.
4. Press the Set button and confirm the entry.
◁
The tool then returns to the normal operating mode.
Printed: 06.06.2016 | Doc-Nr: PUB / 5284788 / 000 / 00
Summary of Contents for PP10
Page 2: ...1 Printed 06 06 2016 Doc Nr PUB 5284788 000 00 ...
Page 4: ...Printed 06 06 2016 Doc Nr PUB 5284788 000 00 ...
Page 88: ...Printed 06 06 2016 Doc Nr PUB 5284788 000 00 ...
Page 89: ...Printed 06 06 2016 Doc Nr PUB 5284788 000 00 ...
Page 91: ...PP 10 Deutsch de Printed 06 06 2016 Doc Nr PUB 5284788 000 00 ...
Page 92: ...1 Printed 06 06 2016 Doc Nr PUB 5284788 000 00 ...
Page 103: ...Printed 06 06 2016 Doc Nr PUB 5284788 000 00 ...