Charging temperature range (also for charging during
operation)
+0…+40°C (32° to +104°F)
Weight
0.3 kg (0.67 lbs)
Dimensions (L x W x H)
160 mm X 45 mm X 36 mm (6.3" x 1.8" x 1.4")
PRA 85 AC adapter
AC supply
115…230 V
AC frequency
47…63 Hz
Rated power
40 W
Rated voltage
12 V
Operating temperature range
+0…+40°C (32°F to +104°F)
Storage temperature range (dry)
-25…+60°C (-13°F to 140°F)
Weight
0.23 kg (0.51 lbs)
Dimensions (L x W x H)
110 mm X 50 mm X 32 mm (4.3" x 2" x 1.3")
5 Safety instructions
5.1 Basic information concerning safety
In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
5.2 General safety rules
a)
Do not render safety devices ineffective and do
not remove information and warning notices.
b)
Keep laser tools out of reach of children.
c) Failure to follow the correct procedures when open-
ing the tool may cause emission of laser radiation in
excess of class 2.
Have the tool repaired only at a
Hilti Service Center.
d)
Take the influences of the surrounding area into
account. Do not use the tool where there is a risk
of fire or explosion.
e) (Statement in accordance with FCC §15.21):
Changes or modifications not expressly approved
by the manufacturer can void the user’s authority to
operate the equipment.
5.3 Proper organization of the work area
a)
Secure the area in which you are working and
take care to avoid directing the beam towards
other persons or towards yourself when setting
up the tool.
b)
Avoid unfavorable body positions when working
from ladders. Make sure you work from a safe
stance and stay in balance at all times.
c) Measurements taken through panes of glass or other
objects may be inaccurate.
d)
Ensure that the tool is set up on a steady, level
surface (not subject to vibration).
e)
Use the tool only within its specified limits.
f) Check that your PR 35 is responding only to your
PRA 35 and not to other PRA 35s that may be in use
on the jobsite.
5.3.1 Electromagnetic compatibility
Although the tool complies with the strict requirements
of the applicable directives, Hilti cannot entirely rule out
the possibility of the tool being subject to interference
caused by powerful electromagnetic radiation, leading
to incorrect operation. Check the accuracy of the tool
by taking measurements by other means when working
under such conditions or if you are unsure. Likewise, Hilti
cannot rule out the possibility of interference with other
devices (e.g. aircraft navigation equipment).
5.3.2 Laser classification for laser class II
appliances
The tool complies with Laser Class 2 in accordance
with IEC825-1:2008 / EN60825-1:2008 and Class II in
accordance with CFR 21 § 1040 (FDA). This tool may be
used without need for further protective measures. The
eyelid closure reflex protects the eyes when a person
looks into the beam unintentionally for a brief moment.
This eyelid closure reflex, however, may be negatively
affected by medicines, alcohol or drugs. Nevertheless, as
with the sun, one should not look directly into sources of
bright light. Do not direct the laser beam toward persons.
5.4 General safety rules
a)
Check the condition of the tool before use. If the
tool is found to be damaged, have it repaired at a
Hilti service center.
b)
The user must check the accuracy of the tool
after it has been dropped or subjected to other
mechanical stresses.
en
21
Printed: 08.07.2013 | Doc-Nr: PUB / 5070234 / 000 / 01
Summary of Contents for PR 35
Page 2: ...ꛈ ꛉ ꛊ ꛋ ꛌ ꛍ ꛎ ꛏ ꛐ ꛑ 1 Printed 08 07 2013 Doc Nr PUB 5070234 000 01 ...
Page 4: ... 6 8 9 7 11 10 Printed 08 07 2013 Doc Nr PUB 5070234 000 01 ...
Page 5: ... 12 13 14 Printed 08 07 2013 Doc Nr PUB 5070234 000 01 ...
Page 6: ...D P P P P F G E 15 5 P P 16 Printed 08 07 2013 Doc Nr PUB 5070234 000 01 ...
Page 7: ... PP 5 17 Printed 08 07 2013 Doc Nr PUB 5070234 000 01 ...