en
12
8.2 Care of the power tool
CAUTION
Keep the power tool, especially its grip surfaces, clean and
free from oil and grease. Do not use cleaning agents which
contain silicone.
The outer casing of the power tool is made from impact-resistant
plastic. Sections of the grip are made from a synthetic rubber
material.
Never operate the power tool when the ventilation slots are
blocked. Clean the ventilation slots carefully using a dry brush.
Do not permit foreign objects to enter the interior of the power
tool. Clean the outside of the power tool at regular intervals with a
slightly damp cloth. Do not use a spray, steam pressure cleaning
equipment or running water for cleaning. This may negatively
affect the electrical safety of the power tool.
8.3 Care of the Li-ion battery
Avoid entrance of moisture.
Charge the battery fully before using it for the first time.
In order to achieve maximum battery life, stop discharging the
battery as soon as a significant drop in performance is noticed.
NOTE
If use of the power tool continues, battery discharge is stopped
automatically (indicated by LED 1 blinking) before the battery cells
suffer damage.
Charge the battery with the Hilti charger approved for use with
Li-ion batteries.
NOTE
– A conditioning charge (as is required with NiCd or NiMH
batteries) is not necessary.
– Interruption of the charging procedure has no negative effect
on battery life.
– Charging can be started at any time with no negative effect
on battery life. There is no memory effect (as with NiCd or
NiMH batteries).
– For best results, batteries should be stored fully charged in a
cool dry place. Avoid charging the battery in places subject
to high ambient temperatures (e.g. at a window) as this has
an adverse effect on battery life and increases the rate of
self-discharge.
– If the battery no longer reaches full charge, it may have lost
capacity due to aging or overstressing. It is possible to
continue working with a battery in this condition but it should
be replaced in good time.
8.4 Maintenance
WARNING
Repairs to the electrical section of the power tool may be
carried out only by trained electrical specialists.
Check all external parts of the power tool for damage at regular
intervals and check that all controls operate faultlessly. Do not
operate the power tool if parts are damaged or when the controls
do not function faultlessly. If necessary, the power tool should be
repaired by Hilti Service.
8.5 Checking the power tool after care and maintenance
After carrying out care and maintenance work on the power tool,
check that all protective and safety devices are fitted and that they
function faultlessly.
9 Troubleshooting
Fault
Possible cause
Remedy
The power tool
doesn’t run.
The battery is dis-
charged or fitted in-
correctly.
The battery must be
heard to engage with
a double click or,
respectively, needs
to be charged.
Electrical fault.
Remove the battery
from the power tool
and contact Hilti Ser-
vice.
Printed: 30.09.2013 | Doc-Nr: PUB / 5152675 / 000 / 01