Power tool
SF 181-A
SFH 181-A
Speed in 2nd gear
0…1,455/min
0…1,380/min
Speed in 3rd gear
0…2,000/min
Torque with tool set to drilling
symbol (soft/flexible joint)
Max. 36 Nm
Max. 36 Nm
Torque range (15 settings)
2…12 Nm
2…12 Nm
Hammering speed
36,000/min
Hammer drilling in brick and
masonry (max. length 100 mm)
1.5…12 mm
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a
standardised test given in EN 60745 and may be used to compare one tool with another. It may be used for a
preliminary assessment of exposure. The declared vibration emission level represents the main applications of
the tool. However if the tool is used for different applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly increase the exposure level over the total working
period. An estimation of the level of exposure to vibration should also take into account the times when the
tool is switched off or when it is running but not actually doing the job. This may significantly reduce the
exposure level over the total working period. Identify additional safety measures to protect the operator from
the effects of vibration such as: maintain the tool and the accessories, keep the hands warm, organisation of
work patterns.
Noise and vibration information (measured in accordance with EN 60745):
Typical A-weighted sound power level for the
SF 181-A
88 dB (A)
Typical A-weighted sound power level for the
SFH 181-A
102 dB (A)
Typical A-weighted emission sound pressure level
for the SF 181-A
77 dB (A)
Typical A-weighted emission sound pressure level
for the SFH 181-A.
91 dB (A)
Uncertainty for the given sound level as per EN 60745
3 dB (A)
Additional information in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
measured in accordance with EN 60745
ತ
2
ತ
2
Screwdriving without impact action, a
h
< 2.5 m/s
t
Uncertainty (K)
1.5 m/s
t
Additional information in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
measured in accordance with EN 60745
ತ
2
ತ
1
Drilling in metal, a
h,D
< 2.5 m/s
t
Hammer drilling in concrete, a
h,ID
13.1 m/s
t
Uncertainty (K) for triaxial vibration measurements
1.5 m/s
t
Battery
SFB 180
SFB 185
Rated voltage
18 V
18 V
Capacity
2 Ah
3 Ah
Energy content
36 Wh
54 Wh
e
n
18
Printed: 07.07.2013 | Doc-Nr: PUB / 5070675 / 000 / 00
Summary of Contents for SFH 181-A
Page 2: ...1 2 3 4 5 6 7 8 9 1 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 3: ...1 2 1 R L STOP 1 3 2 1 1 2 3 3 2 1 2 3 4 5 6 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 17: ...de 14 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 31: ...en 28 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 59: ...cs 56 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 73: ...sk 70 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 89: ...pl 86 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 103: ...hr 100 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 131: ...bg 128 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 157: ...ar 154 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...
Page 171: ...ja 168 Printed 07 07 2013 Doc Nr PUB 5070675 000 00 ...