Types of work
WARNING
Damaged power cords are a safety hazard!
If the supply cord or extension cord is damaged while work
is in progress, immediately disconnect the device and the cord from the electricity supply. Do not touch the
damaged part of the cord.
▶
Regularly check all supply cords. Replace defective extension cords. Have damaged power cords
replaced by a qualified specialist.
Use of a ground fault circuit interrupter (residual current device, RCD) with a maximum tripping current of
30 mA is recommended.
7.1
Dust removal system
The dust extractor reduces dust emissions, increases working safety by providing better visibility of
the cutting line and reduces exposure to dust and wood chips at the workplace.
1. Fit the guard. → page 18
2. Connect the dust removal adapter and the extractor when you intend working for a long period on wood
or other materials, because high concentrations of dust can be produced in these operations.
7.2
Switching on
1. Press the on/off switch.
2. To lock the switch, subsequently press the lockbutton.
3. To release the lockbutton, press the on/off switch again.
7.3
Plunge cutting
1. Set the orbital-action adjusting lever to position 0.
2. Bring the front edge of the base plate into contact with the workpiece.
3. Hold the product securely and press the on/off switch.
4. Press the product firmly against the workpiece and begin the plunge cut by slowly reducing the angle of
attack.
5. Once the blade has penetrated right through the workpiece, bring the product into its normal working
position.
▶
The base plate then lies flat on the working surface.
6. Continue to saw along the cutting line.
7.4
Switching off
▶
Release the on/off switch.
8
Removal
CAUTION
Risk of injury!
Inadvertent starting of the product.
▶
Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
8.1
Removing the suction adapter
1. Press the two retaining catches inwards.
2. Pull the suction adapter to the rear to remove it from the base plate.
3. Disconnect the vacuum cleaner hose from the suction adapter.
8.2
Removing the guard
▶
Tilt the guard slightly and pull it off toward the front.
Summary of Contents for SJD 6
Page 2: ...1...
Page 3: ...2 3 4 5...
Page 4: ...6 7 8 9...
Page 5: ...10 11 12 13...
Page 228: ...222 2143763 2143763 1 1 1 1 2 1 2 1 1 2 2 1 2 3 1 3 1 3 1...
Page 230: ...224 2143763 2143763 2 2 2 3...
Page 231: ...2143763 2143763 225 3 3 1 1 3 2 T 3 3 3 4...
Page 235: ...2143763 2143763 229 7 2 10 1 2 3 7 3 1 0 2 3 4 5 6 7 4 8 8 1 11 1 2 3 8 2 12 8 3 13 1 2 9...
Page 237: ...2143763 2143763 231 12 Hilti Hilti Hilti 13 RoHS qr hilti com r5212956 RoHS QR 14 Hilti...
Page 238: ...232 2143763 2143763...
Page 239: ......
Page 240: ...Hilti registered trademark of Hilti Corp Schaan Pos 1 20200217 2143763 2143763...