1.2
Technical Characteristics
security
3
2
security
Introduction
1
1.1
!
.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Introduction
Features
Antitheft alarm, two delayed loc two ready locations(6 for XRphone line
24h
4 cabled hubs (8 for XR800GSM) or singularly programmable radio hubs.
Module DXR2 included
Management of new radio controls DXR4 that display the correct connection/disconnection and
that warn the memory alarm.
Integrated console endowed with a backlit LCD and management of an additional console DX22
connected on bus RS485.
Infrared sensor DigiPyro with 3 rays, maximum range 5 mt in order to turn the backlit on
automatically on the display and usable keyboard as a detector and at the same time on the
delayed area number 1
Connection for the remote control command accessories type PXR, SK and KBC and output (V
and R) in order to inform about the status of the system with LED.
Output for the automatic activation of the external devices (Eg: Lights, Furnaces etc.) about
connection / disconnection of the system or on local command from the console o from the
remote control through phone call communication.
!
Management of the new charger (AL35EN) with control and visualization of the voltage, of the
charge of the efficiency of the battery, of the voltage of power source and of the presence of the
network connection on the display of the console.
Two modalities of partialization of the system selectable from the console, from connectors, from a
remote controller or through remote connection GSM.
Possibility to use proximity sensors DX100/DX300 (maximum 4) in order to choose the modality of
partialization and for the related command.
New line of connection RS485 with protocol “DX bus” for the connection of the new peripheral
devices of the series DX.
Telephone dialer GSM with preregistered voice mail and SMS and customizable voice mail of 10
seconds, with GSM module Quad Band.
Sendable SMS with the status of the system report, identification of the area and warning about
the status of the power source.
Telephone alarm and warning about the status of the system, status of the areas, status of the
power source and alarm memory with pre-recorded voice.
Voice guidance menu in order to use it locally o through telephone connection for the command
and or query of the status of the central computer and of the areas and for the exclusion of the
areas
Voice responder with the activation of the guide for the menu.
`
Listening environment during the phone connection.
Telephone notice for the prolonged absence of the power source of the network.
Indication of the telephone company and of intensity of the signal on the display.
Query of the phone credit left through the return of SMS.
Optional return of the received messages SMS.
Telephone book of 16 numbers
Case made of ABS with a battery compartment B12V7, 5A.
Degree of safety: 1
Environmental class: 2
Possibility to remove completely the front panel in order to access inside the case.
Board for connections on the base of the case with activation of maintenance mode (Keeps the
power source on the external siren with the removed front panel), for an easy wiring and an
ordered cabling ( EASY CONNECT SYSTEM) with a base for the connection of the radio module
DXR2.
Anti Tamper and anti opening Tamper.
Nominal supply voltage
Immediate Protection Zones
Outcoming services
Compartment for buffer battery
Duration programmable alarm
Programmable Time of the coming out
Programmable Time of the coming in
Security level
Outer container
Dimensions (L)
Dimensions(A)
Dimensions(P)
Degree of protection of the container
Tamper protection zones “24” h
Environmental class
Operating temperature
Delayed Protection Zones
Complying with the norm
Angle of coverage of the detector on the panel
Numbers in the phone book
Maximum coverage of the detector on the panel
Maximum output current of outcoming services
Maximum absorption (central computer only)
Total power supplied from the power source
Maximum absorption
230V~ ±5% 50Hz
2
Battery B 12V7.5 Ah
1
ABS
From 0 ÷ 60 sec
From 180 to 600 sec.
IP40
13,5Vcc ±10%
from 0 ÷ 60 sec
1 + Tamper
2
+5°C ÷ +40°C
2
CEI EN 50131-1
H: 85°; V: 60°
16
5mt
1A
65mA@230Vac
35W (2,6Ah a 13,5V)
160mA@230Vac
280mm
230mm
96mm
6
XR400GSM
XR800GSM
XR400GSM
- XR
800GSM - Installation guide and use