5.3.1
Commands of the voice Menu
0- DISCONNECT
This command is listed when the central is connected only and it is useful to disconnect the central.
After the execution of the command the voice guide indicates a new status of the central
<System disconnected>
and restarts listing the options from the voice menu.
1
-STOP CYCLE
The command
STOP CYCLE
ends every eventual ongoing cycle of alarm, it turns off the sirens and
doesn't carry out more calls of alarm.
Once the command is executed the voice guide continues to indicate the available options.
2-
ALARM MEMORY
It communicates to the user what are the zones that were memorized because there was an alarm during
the last connection of the central.
The message is like this:
< There are no zones with alarms>
when the memory is empty.
Or:
< The zones with alarm are: zone 1, zone 4...zone 24 hours>
With the list of all
the areas inserted in the alarm memory.
At the end, the leading voice restarts to indicate the available options.
3 - EXCLUSIONS OF THE ZONES
Dial to access to the menu of exclusion of the zones : the leading voice indicates:
<There are no excluded zones>
or
<The excluded zones are: zone 2,... zone 24 hours>
with the list \
of the excluded zones.
<Dial the number of the zone, press 9 for 24 hours or press asterisk for the former menu>.
Press the number of a zone in order to modify it (ex. ) and the leading voice continues with:
<zone 4> or <zone 4 included>
if the zone was excluded.
The leading voice restarts then to repeat the status of the excluded zones and waits you to dial in
order to come back to the main menu
4 - OPEN ZONES
Dial in order to listen to the list of the zones that result to be open.
This command results useful during the remote connection, when it is not possible to visualize the panel
of the central with the led and the display that signal the open zones.
<There are no open zones>
or
<The open zones are: zone 4, zone 24 hours>
At the end the leading voice restarts to indicate the options of the main menu.
4
4
3
4
5.3
Leading voice
Once you access the voice menu, the leading voice provides you with the indications of the status of
the central:
<Alarm system>
, or
<Alarm 24h>
if the central is carrying out an alarm.
< System disconnected>
or
<System enabled totally>
or
<System enabled partially A>
or
<System enabled partially B>
<Network OK>
or
<Absence of network>
The leading voice lists the available options:
<Press 0 to disconnect >
(only with the central connected)
<Press 1 to stop the cycle>
<Press 2 to activate the alarm memory>
<Press 3 to exclude the zones>
<Press 4 for open zones>
<Press 5 to listen to environment sounds >
(during the remote connection only)
<Press 6 to activate the output >
(with the INT programmed for the command
functioning),
<Press 7 to enable the central totally
8 for partial A or 9 for partial B>,
(with the central disconnected only).
Press one the indicated buttons to access the related function.
If you don't send commands from the console or from the remote telephone, the menu switches off and
the voice indications end.