6.3 - Commands
6.3.1 - INSERTING THE SYSTEM
From the panel of the central it is necessary to verify that the immediate zones aren't open: check that the
related LEDs aren't active and eventually close doors and windows or leave the environments to be sorveilled
by the sensor that keep the zone in alarm. The opening of the delayed xzone doesn't avoid to insert the central
, but it is necessary that at the end of the time of programmed output, the delayed line will be closed again. It’s
possible to exclude invidually the zones
And dial or or dial after the code
On the display if the command is allowed appear the writing :
Followed by indication:
The insertion can be done also in the partial mode, according one of the two partialisation patterns
configured at programming. To select then in the commands menu one of the options:
o
And dial or or, as usual, dial the USER code followed by and or .
(except the 24h) to submit to monitoring by pressing for a few
seconds the number of the zone to exclude (or to include again ).
When commands the central unit from panel , from console DX22, from connector DX100 / DX300 or from
connecting call, it’s possible to select a partial insertion that indicates the esxclusion of monitoringof some
zones,like programmed.
From panel or from console
: dial the USER code and to select the menu :
1
2
3
4
7
7 -
A r m A L L A r e a s
D i s a r m e d
7
E x i t T O T
S e r v . P r o v . E N
I n s E n a b l e d T O T
S e r v . P r o v . E N
8 P a r t . I n s . A
I n s . D e s a b l e d
9 P a r t . I n s . B
I n s . D e s a b l e d
8
9
security
48
Toconnect the installation from the panel of the central unit, by using the guide from voice menu ,
dial to activate the guide and,following the indications to insert the code and then dial for total
connection ,
Or to connect the partial A installation.
Or to connect the partial B installation. .
To command the central unit from remote control through telephone network,one time activated the
connection with the central unit , it’s possible to follow the voice guide similar to what happen from the
panel with the voice menu :
USER code , to total connection, or , to partial A connection, or
to partial B connection .
8
9
7
8
9
7
To connect the central unit with the
PXR readers or through command KB devices
, to verificate the
LED placed on the device :
The RED LED on indicates that an immediate zone not excluded is opened and the connection will not
executed if the zone takes place will not executed if the zone takes place of the partialisation pattern
configurated for KEY entry.
The RED LED that off for a moment every second, indicates that a delayed zone (1 or 2) is opened ant
that the connection command will be executed; if the zone will be opened at the end of the exit time, will
be generated a round of alarm.
On command executed the two LEDs red and green flashing at the same time for all the the exit time,and
mat the end off. If however the command doesn’t executed, the two LED emit tha fast flashing for a few
moments of seconds and at the end the green LED stays on.
The meaning of LED of conenctor is indicated in the following table:
For the connection of the central unit through
Dx100
readers with the choice from time to time of the
favorite partialisation pattern, refers to section "ELECTRONIC KEY DX100"
NOTE: When the central unit is on alert 24h, the connection command off the sirens et cancel sirene ethe
round of the GSM calls,but doesn’t connect the installation; to connect the burglar alarm system it
is necessary then to repeat the command, after restored the 24H zone.
GREEN LED
Alarm
Memory
to desabled
central unit
RED LED
Installation
desabled
and ready
GREEN LED
and RED
ON
1 FLASHING
TO SECOND
FLASHING
Excluded zones
to
desabled
installation
Immediate
zone opened
to desabled
central
unit
OFF
Enabled
installation
Zone
chiuse
Opened
delayed
zone
24H opened
line
1 FLASHING
INVERSE
TO SECOND
Alarm
current
or
exit time
FAST
FLASHING
Command of
connection
not executed
security
Use of the central unit
49
XR400GSM
- XR
800GSM - Installation guide and use