background image

INSTALLING YOUR PUREIT ULTIMA ECO

MINERAL RO+UV+MF PURIFIER

CLEANING & MAINTENANCE

TAKING CARE OF YOUR PUREIT ULTIMA

ECO MINERAL RO+UV+MF PURIFIER

1.  Use only the plug provided with the purifier.
2.  The purifier should not be connected to any hot water tap. Do not run hot water 

over 45°C through the purifier.

3.  Water from waste water tube is not suitable for drinking. You can use that water 

for gardening or to clean floors.

4.  Store water only in the purifier and don’t use other bottles and containers. If you 

do so, water may get contaminated.

1.  The purifier should be installed by a trained Pureit technician.
2.  It can be wall-mounted or used as a table top purifier.
3.  The purifier should be placed in area which is free of ants/insects/other pests.
4.  The purifier should be placed close to the plumbed inlet connection
  (not more than 2 metres).
5.  Do not install the purifier above any electric socket.
6.  Avoid sharp bends to the pipes of the product.
7.  Do not use an extension cord.
8.  Make sure you test the input water TDS (Total dissolved salts) before installing 

the purifier. The maximum input TDS should not exceed 2000 PPM.

Dispenser

1. Do not use detergents, soap or wet cloth to clean the external parts. Use dry and 

soft cloth to clean the front cover. It is recommended to use a 3M mop cloth for this. 

2. Clean the dispenser by using disinfectants like bleach/hypochlorite (50 PPM 

available chlorine). Discard 2 litres of water after cleaning the dispenser.

3. Do not use any cleaning solution to clean the Digital Display Panel. Damages 

ensuing thereof are not covered under warranty.

Storage Tank

1. Discard the water in the storage tank once in 15 days. 

2. Drain the water in the storage tank if purifier is not used for 2 days.

3. Clean the storage tank once a month with disinfectant solution. To purchase this 

  solution, call us at 1860-210-1000 now. 

4. How to clean the tank: Open the cleaning solution dispenser and put 1 ml of the 

  disinfectant solution (10–15 drops) into the storage tank. (Ensure the tank is full).

  Drain the entire tank after 10 minutes.

5. No foreign material (like dust/ants/insects/other pests) should enter the storage 

tank. The filtered water in the storage tank may deteriorate in the process.

6. The point-of-use reverse osmosis drinking water treatment systems addressed by 

NSF-58 standard are designed to be used for the reduction of specific substances 

that may be present in drinking water supplies (public or private) which are 

considered to be microbiologically safe and are of known quality.

7. The output water may continue to have flora which are harmless and pose no

health hazard to normal healthy adults and children.

3

Disposal Guidelines (Electrical): To prevent possible harm to the environment or human health from uncontrolled 

waste disposal, please separate electrical items in this product such as power supply adaptor, control circuits, 

LED panel, and wiring from other types of waste and recycle them responsibly to promote sustainable use of 

material resources. Contact either the retailer where you purchased this product, or local government office for 

details of where and how these items can be taken for environmentally safe recycling.

Summary of Contents for Pureit Ultima Eco

Page 1: ...I N S T R U C T I O N M A N U A L Welcome to the Pureit family WITH A NEW WATER DRINKING EXPERIENCE ...

Page 2: ...RO UV MF PURIFIER 1 5 6 7 1 4 3 2 01 Digital display panel 02 Soft touch button 03 Water dispensing outlet 04 Light assisted water dispensing 05 Pre sediment filter 06 Inlet water tube 07 Reject water tube 08 Cleaning solution dispenser 8 ...

Page 3: ... cysts 5 UV Chamber Acts as an additional stage of purification to further inactivate bacteria virus and parasites to deliver safe water 6 Post RO Carbon Filter This level of purification acts as a polisher and enhances the taste of purified water 7 Micro Filtration Membrane Micro Filtration Membrane is stage after Post RO and UV which ensures that the water is purified not once but thrice PUREIT ...

Page 4: ...olution to clean the Digital Display Panel Damages ensuing thereof are not covered under warranty Storage Tank 1 Discard the water in the storage tank once in 15 days 2 Drain the water in the storage tank if purifier is not used for 2 days 3 Clean the storage tank once a month with disinfectant solution To purchase this solution call us at 1860 210 1000 now 4 How to clean the tank Open the cleanin...

Page 5: ... 10 In case of any smoke or burning smell switch off power remove the plug immediately and call us at 1860 210 1000 ATTENTION Close the ball valve before opening SF housing for cleaning Please do not use any abrasive pointed tool to clean the Sediment Filter as it may damage the Sediment Filter In case you observe the rubber ring is dirty clean the rubber ring fix it on the housing again properly ...

Page 6: ...e filters at a nominal cost TANK FULL Blue N A GKK is safe to use Last bar of the GKK circle blinks CHANGE GKK blink at the centre of the panel and the call centre number 1860 210 1000 illuminated at the bottom of the panel Blinking for GKK will occur to replace filter after approximately 260 hours of pump running time GKK life will end soon Please contact the Pureit helpline to replace your GKK L...

Page 7: ...ill guide you on the repairs required You would need to buy the replacement parts at an additional cost What should I do if there is a leakage from the purifier Turn off the Ball Valve and switch off the power if you find any failure Check for any visually improper fitments and then call our Pureit Helpline at 1860 210 1000 and register a service request How long the stored water in Pureit Ultima ...

Page 8: ...To know more Contact Pureit helpline number 1860 210 1000 Or Visit www pureitwater com ...

Reviews: