HYBRID/TROUBLE SHOOTING
3–170
1.
For the 11th terminal of PCU harness (16P) lower-side connector,
inspect the signal line of PCU wire harness (lower side) for short
circuit. (See "Inspecting the PCU harness signal line for short cir-
cuit.")
NO
YES
1.
Set the starter key to the "LOCK" position.
2.
Connect all the connectors that have been disconnected.
3.
Disconnect the connector of HV battery cooling fan.
4.
Set the starter key to the "ON" position.
5.
Using the electrical tester, measure the voltage between the con-
nector terminals of HV battery cooling fan.
NO
YES
7
Inspecting the signal line of PCU wire harness (lower side) for short circuit
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
PCU harness (16P)
lower-side con-
nector
11th terminal
–
Each signal line
10 k
or more
Is any defect found?
Replace the PCU wire harness (lower side).
Go to step 8.
8
Inspecting the voltage of PCU wire harness (upper side)
SHTS03ZZZ0300117
Measurement
conditions
Tester
connections
Standard values
Starter key: ON
HV battery cool-
ing fan connector
3rd terminal
–
4th terminal
9 V or more
Is the measured value within the range of standard value?
Go to step 9.