HYBRID/TROUBLE SHOOTING
3–174
5
Inspecting the
continuity of
PCU wire har-
ness (lower
side)
1. Set the starter key to the
"LOCK" position.
2. Disconnect the HV ECU2 con-
nector.
3. Using the electrical tester, mea-
sure the resistance between
the lower-side connector termi-
nal of PCU harness (16P) and
the HV ECU2 connector termi-
nal.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (16P) lower-side
connector
–
HV ECU2 connector
11th terminal
–
18th terminal
<Standard values>
Less than 1
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 6.
Replace the
PCU wire har-
ness (lower
side).
6
Inspecting the
PCU wire har-
ness (lower
side) for short
circuit
1. Using the electrical tester, mea-
sure the resistance between
the lower-side connector 11th
terminal of PCU harness (16P)
and the ground.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (16P) lower-side
connector
11th terminal
–
GND
<Standard values>
10 k
or more
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 7.
Replace the
PCU wire har-
ness (lower
side).
7
Inspecting the
signal line of
PCU wire har-
ness (lower
side) for short
circuit
1. For the 11th terminal of PCU
harness (16P) lower-side con-
nector, inspect the signal line of
PCU wire harness (lower side)
for short circuit. (See "Inspect-
ing the PCU harness signal line
for short circuit.")
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (16P) lower-side
connector
11th terminal
–
Each signal line
<Standard values>
10 k
or more
Defect is
found: Go to
YES.
Defect is not
found: Go to
NO.
Replace the
PCU wire har-
ness (lower
side).
Go to step 8.
P0A84 (TC66)
Abnormality in HV battery cooling fan
drive signal Low
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No