HYBRID/TROUBLE SHOOTING
3–202
1.
Disconnect the 13th and 14th terminals from the high-voltage J/B
(in the ECU box), and then remove the frame wire.
2.
Using the electrical tester, measure the insulation resistance
between the terminals of high-voltage J/B (in the ECU box) and
the ground.
NO
YES
9
Inspecting the insulation resistance of high-voltage J/B (in the ECU box)
9 (BATT+)
10 (BATT-)
SHTS03ZZZ0300137
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
High-voltage J/B
(in the ECU box)
9th terminal
–
10th terminal
9th terminal
–
GND
10th terminal
–
GND
10 M
or more
Is the measured value within the range of standard value?
Go to step 10.
Replace the high-voltage J/B (in the ECU
box).