HYBRID/TROUBLE SHOOTING
3–277
1.
Disconnect the BATT OUT (+) [5] and BATT OUT (-) [6] terminals
from the high-voltage J/B (in the battery pack), and then remove
the frame wire.
2.
Using the electrical tester, measure the insulation resistance
between the terminals of high-voltage J/B (in the battery pack) and
the ground.
NO
YES
5
Inspecting the insulation resistance of high-voltage J/B (in the battery pack)
BATT OUT(-)[6]
BATT IN(-)[4]
BATT OUT(+)[5]
BATT IN(+)[3]
SHTS03ZZZ0300187
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
High-voltage J/B
(in the battery
pack)
3rd terminal
–
GND
4th terminal
–
GND
5th terminal
–
GND
6th terminal
–
GND
10 M
or more
Is the measured value within the range of standard value?
Go to step 6.
Replace the high-voltage J/B (in the battery
pack).