HYBRID/TROUBLE SHOOTING
3–315
1.
Set the starter key to the "LOCK" position.
2.
Remove the inverter start relay.
3.
Using the electrical tester, measure the resistance between the
3rd and 5th terminals of inverter start relay. (With no voltage
applied)
4.
Apply the voltage of 12 V between the 1st and 2nd terminals of
inverter start relay and measure the resistance between the 3rd
and 5th terminals. (With voltage applied)
NO
YES
6
Inspecting the inverter start relay
3
5
1
2
SHTS03ZZZ0300213
Measurement
conditions
Tester
connections
Standard values
Starter key: ON
Inverter start relay
3rd terminal
–
5th terminal
Without voltage:
10 k
or more
With voltage:
less than 1
Is the measured value within the range of standard value?
Go to step 7.
Replace the inverter start relay.