HYBRID/TROUBLE SHOOTING
3–326
1.
For the 1st terminal of inverter start relay connector (relay block),
inspect the signal line of PCU wire harness (lower side) for short
circuit. (See "Inspecting the PCU harness signal line for short cir-
cuit.")
NO
YES
3
Inspecting the signal line of PCU wire harness (lower side) for short circuit
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Inverter start relay
connector
1st terminal
–
Each signal line
10 k
or more
Is any defect found?
Replace the PCU wire harness (lower side).
Replace the HV ECU.