HYBRID/TROUBLE SHOOTING
3–416
Motor discharge allowable torque MG discharge allowable torque
0 - 65,535
Nm
Motor charge allowable torque
MG charge allowable torque
0 - 65,535
Nm
Motor required revolution
Required revolution
-32,768 - 32,767
r/min
Torque/revolution control status
0: Torque, 1: Revolution
0, 1
—
Gate control
(HV ECU instruction)
0: OFF, 1: ON
0, 1
—
System main relay (SMR) off
request
0: No request, 1: Requested
0, 1
—
Service plug lock
0: Lock (ON), 1: Unlock (OFF)
0, 1
—
Inverter stop (FINV)
0: OFF, 1: ON
0, 1
—
Inverter overvoltage (OVINV)
0: OFF, 1: ON
0, 1
—
Gate state
0: Normal, 1: Shutoff
0, 1
—
System main relay 2 (SMR2)
0: OFF, 1: ON
0, 1
—
System main relay 3 (SMR3)
0: OFF, 1: ON
0, 1
—
System main relay 1 (SMR1)
0: OFF, 1: ON
0, 1
—
Motor control mode
0: Sine wave, 1: Overmodulation, 2: Square wave
0 - 2
—
Carrier frequency
0: 5 kHz, 1: 2.5 kHz, 2: 1.25 kHz
0 - 2
—
Emergency start request
0: Without, 1: With
0, 1
—
Power supply voltage
+B power supply
0 - 40
V
Inverter start signal voltage
ON signal voltage
0 - 40
V
System main relay (SMR) drive
12V voltage
SMR drive 12 V voltage
0 - 20
V
Current crowding judgment
0: Without crowding judgment, 1: With crowding
judgment
0, 1
—
Engine intake air temperature
Engine intake air temperature
-40 - 210
C
Inverter short circuit (without
phase judgment)
0: Normal, 1: Abnormality
0, 1
—
Inverter short circuit (with phase
judgment)
0: Normal, 1: Abnormality
0, 1
—
Shorted phase (1 phase/multiple
phases)
0: Not detected, 1: 1 phase, 2: Multiple phases
0 - 2
—
Shorted phase (U phase, V
phase, W phase)
0: U phase, 1: V phase, 2: W phase
0 - 2
—
Shorted phase (upper arm/ lower
arm)
0: Not detected, 1: Upper arm, 2: Lower arm
0 - 2
—
Item
Description
Display range
Unit