HYBRID/TROUBLE SHOOTING
3–423
DTC: P0562 (TC96)
EN01H03ZZZ030602004006
DTC: P0562 (TC96) Abnormality in power supply voltage
INFORMATION
1.
Technical description
•
–
<Description of malfunction>
•
Detected a voltage abnormality in the SMR power supply.
2.
DTC set condition
(1)
DTC detection condition
•
Control power supply voltage is 8 V or more.
(2)
Judgement criteria
•
The state in which SMR power supply voltage is less than 7.5 V is detected continuously for 0.05 second.
3.
Reset condition
•
The state in which SMR power supply voltage is 7.5 V or more and 16.5 V or less is detected continuously for 0.2
second.
4.
Indication, warning or system control regulation when the DTC is set.
•
MIL: OFF
•
HV warning light: ON
HV
ECU
Inverter
starter relay
PCI_B_2 20A
F
F
F
M
F
L
X
L
L
L
I
H
2
2
5
1
3
F_HV_10A
2
3
3
4
1
1
75
H
76
J
43
Inverter
coolant pump
Inverter coolant
radiator fan
E
3
1
2
F
M
E
Inverter
D
25
D
30
D
31
D
10
D
11
16
ON
+B
GND1
X
X
SHTS03ZZZ0300277