HYBRID/TROUBLE SHOOTING
3–429
1.
Remove the inverter start relay.
2.
Using the electrical tester, measure the resistance between the 1st
terminal of inverter start relay connector (relay block side) and the
ground.
NO
YES
1.
Connect all the connectors that have been disconnected to restore
the system.
2.
Connect the diagnosis tool (HINO-DX) to the vehicle.
3.
Set the starter key to the "ON" position.
4.
Clear the malfunction history.
5.
Perform a test run. (accelerate and decelerate running for approxi-
mately 1 hour).
6.
In [Fault Information] on the diagnosis tool screen, check if P0562-
96 is detected.
NO
YES
6
Inspecting the PCU wire harness (lower side) for short circuit 2
Vehicle GND
SHTS03ZZZ0300283
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Inverter start relay
connector (relay
block side)
1st terminal
–
GND
10 k
or more
(No continuity)
Is the measured value within the range of standard value?
Go to step 7.
Replace the PCU wire harness (lower side).
7
Reproduction check [HINO-DX]
SHTS03ZZZ0300284
Is DTC P0562-96 detected?
Replace the inverter.
The inspection is completed.
(Temporary actuation of protection function
due to external noise)