HYBRID/TROUBLE SHOOTING
3–572
4
Reproduction
check [HINO-
DX]
1. Set the starter key to the
"LOCK" position.
2. Connect all the connectors that
have been disconnected to
restore the system.
3. Set the starter key to the "ON"
position.
4. Clear the malfunction history.
5. Perform a test run (accelerate
and decelerate running for
approximately 1 hour).
6. In [Fault Information] on the
diagnosis tool screen, check if
P0A2F-33 is detected.
HINT
Monitor [Motor temperature] on
the data monitor to check that
the temperature is less than
100
C {212
F}.
DTC P0A2F-
33 is detected:
Go to YES.
DTC P0A2F-
33 is not
detected: Go
to NO.
Replace the
inverter.
The inspec-
tion is com-
pleted.
P0A2F (TC33)
Abnormality in motor temperature
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No