HYBRID/TROUBLE SHOOTING
3–595
INSPECTION PROCEDURE: P0A3F (TCB7)
1.
Set the starter key to the "LOCK" position.
2.
Disconnect the resolver connector.
3.
Using the electrical tester, measure the resistance between the
terminals of resolver connector.
NO
YES
1
Inspecting the resolver (sensor)
SHTS03ZZZ0300386
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Resolver connec-
tor
8th terminal
–
4th terminal
6th terminal
–
2nd terminal
7th terminal
–
3rd terminal
(All are equivalent
to ambient tem-
perature 25
C
{77
F}.)
7.2
1.44
26.8
5.36
28.5
5.7
Is the measured value within the range of standard value?
Go to step 2.
Replace the HV motor.