HYBRID/TROUBLE SHOOTING
3–686
7
Reproduction
check [HINO-
DX]
1. Connect all the connectors that
have been disconnected to
restore the system.
2. Set the starter key to the "ON"
position.
3. Clear the malfunction history.
4. Perform a test run. (accelerate
and decelerate running for
approximately 1 hour).
5. In [Fault Information] on the
diagnosis tool screen, check if
P0AA4-D9 is detected.
DTC P0AA4-
D9 is detected:
Go to YES.
DTC P0AA4-
D9 is not
detected: Go
to NO.
Replace the
inverter.
The inspec-
tion is com-
pleted.
(Temporary
actuation of
protection
function due to
external noise)
P0AA4 (TCD9)
SMR#1 and 3 (negative side) contact sticking
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No