HYBRID/TROUBLE SHOOTING
3–694
DTC: P0ADC (TC93)
EN01H03ZZZ030602004056
DTC: P0ADC (TC93) SMR#2 (positive side) High abnormality
INFORMATION
1.
Technical description
•
–
<Description of malfunction>
•
Detected a disconnection (High abnormality) in the SMR#2 (positive side terminal).
2.
DTC set condition
(1)
DTC detection condition
•
Control power supply voltage is 8 V or more.
(2)
Judgement criteria
•
A disconnection in SMR#2 output is detected continuously for 0.06 seconds.
3.
Reset condition
•
Normal output of SMR#2 is detected continuously for 0.06 seconds.
4.
Indication, warning or system control regulation when the DTC is set.
•
MIL: ON
•
HV warning light: ON
Inverter
High voltage J/B
High voltage J/B
D
38
39
40
CON3-38 CON1
CON4-39 CON2
CON4-40 CON3
F-
F+
15
2
3
4
SMR1
SMR2
SMR3
HV Battery 288 V
Service plug
D
D
P
l
m
p
J/B (+)
k
n
q
J/B (-)
P
P
P
SHTS03ZZZ0300457