HYBRID/TROUBLE SHOOTING
3–707
CHECKLIST: P0ADF (TC1E)
P0ADF (TC1E)
SMR#3 (negative side) Low abnormality
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No
1
Inspecting the
PCU wire har-
ness (lower
side) for short
circuit
1. Set the starter key to the
"LOCK" position.
2. Disconnect the connectors of
inverter and PCU harness
(16P).
3. Using the electrical tester, mea-
sure the resistance between
the 40th terminal of inverter
connector and the ground.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
Inverter connector
40th terminal
–
GND
<Standard values>
10 k
or more (No continuity)
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 2.
Replace the
PCU wire har-
ness (lower
side).
2
Inspecting the
wire harness
in the HV bat-
tery for short
circuit
1. Remove the PCU top cover.
2. Disconnect the SMR drive con-
nector from the high-voltage J/
B (in the battery pack).
3. Using the electrical tester, mea-
sure the resistance between
the 4th terminal of PCU har-
ness (16P) upper-side connec-
tor and the ground.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (16P) upper-side
connector
4th terminal
–
GND
<Standard values>
10 k
or more (No continuity)
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 3.
Replace the
PCU wire har-
ness (upper
side).
3
Inspecting the
high-voltage J/
B (in the bat-
tery pack) for
short circuit
1. Using the electrical tester, mea-
sure the resistance between
the 1st terminal of SMR drive
connector and the ground.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
PCU harness (16P) upper-side
connector
1st terminal
–
GND
<Standard values>
10 k
or more (No continuity)
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 5.