HYBRID/TROUBLE SHOOTING
3–742
DTC: P0AF0 (TC25)
EN01H03ZZZ030602004064
DTC: P0AF0 (TC25) Inverter temperature sensor High abnormality
INFORMATION
1.
Technical description
•
–
<Description of malfunction>
•
Detected a High abnormality in the temperature sensor in the inverter (main circuit element temperature sensor).
2.
DTC set condition
(1)
DTC detection condition
•
Control power supply voltage is 8 V or more.
•
Inverter start signal is ON.
(2)
Judgement criteria
•
The state in which the voltage of main circuit element temperature sensor is more than 4.86 V is detected for
0.1 second or more.
3.
Reset condition
•
The state in which the voltage of main circuit element temperature sensor is 0.19 V or more and 4.86 V or less is
detected continuously for 0.2 second.
4.
Indication, warning or system control regulation when the DTC is set.
•
MIL: ON
•