63
8.5 ELECTRONIC BOARDS LIGHT MEANINGS
The master board (ECM1-2) is composed by two modules, the front module
called ECM2 and the back module called ECM1.
8.5.1 ECM2 (MASTER BOARD FRONT MODULE) LED CODE :
With LED steady ON
DL1 green LED ON: Power +5V to MASTER BOARD FRONT MODULE CPU
DL2 yellow LED ON: All the outriggers are lifted from the ground or machine is
closed and aligned (photocells signal)
DL3 yellow LED ON: All the outriggers are touching the ground or all the
outriggers are lifted from the ground
\
DL1
DL2
DL3