The LED for a failure flashes periodically, as shown in the following figure.
Example: in the case of "2 flashes” the sequence of 0.3 sec. ON > 0.3 sec. OFF
> 0.3 sec. ON > 1.5 sec. OFF is repeated as a cycle.
HONDA IGX 440 QUICK TROUBLESHOOTING
LED Status
• Possible problems
Engine behavior
LED
illumination
• None (Electrical system is
normal)
Normal
2 flashes
• Insufficient oil
While engine is running: Engine
stops
• Oil level switch failure
At start up: Engine may not start
• Wire harness connecting oil
level switch and Engine control
unit failure
• Engine control unit failure
4 flashes
• Engine temperature sensor
failure
While engine is running: Engine
continues to run
• Wire harness connecting
engine temperature sensor and
Engine control unit failure
At start up: Engine does not start
• Engine control unit failure
6 flashes
• Power coil failure
While engine is running: Engine
stops
• Wire harness connecting
power coil failure and Engine
control unit failure
At start up: Engine does not start
• Engine control unit failure
8 flashes
• Program failure
While engine is running: Engine
stops
At start up: Engine does not start
LED is not
lighted
• Battery failure
While engine is running: Engine
stops
• 3A or 30A fuse blown
At start up: Engine does not start
• Combination switch failure
• Wire harness failure
• Engine control unit failure
(*1): The engine may or may not stop, depending on the program in the
Engine control unit.
(*2): Rewriting of the program is needed. Contact your Honda engine valve
block.
Summary of Contents for LightLift 17.75 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 17 75 3S LightLift 20 10 3S PERFORMANCE TTPE1720021602 ...
Page 6: ...6 2 2 1 LL17 75 3S PERFORMANCE DIMENSIONS NOTE standard version with 2 persons basket ...
Page 7: ...7 2 2 2 LL17 75 3S PERFORMANCE WORKING AREA 230 KG CAPACITY ...
Page 8: ...8 2 3 1 LL20 10 3S PERFORMANCE DIMENSIONS NOTE standard version with 2 persons basket ...
Page 9: ...9 2 3 2 LL20 10 3S PERFORMANCE WORKING AREA 230 KG CAPACITY ...
Page 43: ...43 HATZ 1B40 EMERGENCY START FOR 17 75 DIESEL ...
Page 44: ...44 PERKINS 402 05 EMERGENCY START FOR 20 10 DIESEL ...
Page 93: ...93 ...
Page 94: ...94 ...
Page 101: ...101 APPENDIX 1 HYDRAULIC SYSTEM 1st part GROUND PART ...
Page 102: ...102 HYDRAULIC SYSTEM 2nd part AERIAL PART ...
Page 103: ...103 HYDRAULIC SYSTEM LIGHTLIFT CAPTION GROUND PART AERIAL PART ...