43
4.1 General Specifications
Specifications
Chapter 4
4.1 General Specifications
Measurement
Method
Dual integration
AC Measurement
System
True RMS measurement
Function
DC voltage (
V), AC voltage(
V),
Resistance (
), DC current (
A),
AC current (
A), Continuity check (
),
Diode check (
), Frequency (Hz),
Duty factor (
)
Additional
Function
Auto Range function
Manual Range function
Hold function
Hold Auto function
Relative Display Function
Dynamic Recording function
Memory function (Registration, call, deletion)
Auto Power Save function
Overflow Warning function
Battery-Life Warning function
Display Type
TN type LCD, 1/4 duty, dynamic drive
Display Elements
3(1/2) dgt.
Max. 4200 counts (19,999 counts for Hz
function)
Number display: "20"
Polarity indicator: "–" sign (automatic)
Overflow indicator: "OF" or "–OF"
Units and Symbols AUTO/
/REL/HOLD/MAX/MIN/AVG/
/
/APS
M/k/m/
/Hz/
/A/V/%/
/
/
/MEM
Bar-graph
Indicator
Indication of scale, 42-dot bar graph, and ±
(polarity)