3.6 Measuring Duty by Timer
47
1
2
3
4
5
6
7
8
9
10
B
asi
c M
easu
rem
e
nt
Proce
dure
7.
Press
SHIFT
→
(
INPUT/SET
) to dis-
play the timer display.
8.
Press
SHIFT
→
(
INPUT/SET
) to dis-
play the numerical entry display.
9.
Press the
buttons to enter 24
hours.
10.
Press
SHIFT
→
(
INPUT/SET
) to
accept the entered values.
11.
Press the
button to display the
duty.
Although no "%" unit indicator appears, the
displayed value is percentage.
12.
Clamp around a conductor to be mea-
sured so that it is centered in the
clamp.
13.
Press
SHIFT
→
(
START/STOP
) to
start duty measurement.
START
and
TIME
are displayed.
14.
Press
SHIFT
→
(
START/STOP
)
again to stop duty measurement.
STOP
is displayed.
Electric
conductor
The 9691 CLAMP ON AC/DC SENSOR
Clamp direction is
irrelevant
Blinking
Blinking
Summary of Contents for 3290-10
Page 1: ...CLAMP ON AC DC HiTESTER INSTRUCTION MANUAL 3290 10...
Page 2: ......
Page 6: ...iv Contents...
Page 14: ...8 Usage Notes...
Page 42: ...36 2 5 Turning Power On and Off...
Page 54: ...48 3 6 Measuring Duty by Timer...
Page 149: ...4 5 6 7 8 9 10 11...
Page 150: ......