34
❶
Allowable range (Rate (R))
This specifies the allowable range to the pass / fail criteria.
❷
<Counter>
You can set whether to use all of the functions including pulse counting, screw counter, etc. If [Off] is
set, no data is sent.
❸
<Screw counter>
Here you set the number of screws to be fastened.
❹
<Minimum pulse> / <Maximum pulse>
Here you set the upper threshold for pass / fail of screw fastening.
❺
<Work reset timer>
Here you set the length of the buzzer when the number of screws set by <Screw counter> is
completed.
In addition, a reverse operation within the specified time cancels the count down when the set
number of screws is completed.
❻
<Count timer for reverse rotation>
When the reverse counting time of <System> is active, here you specify the operation time before
you can cancel the last count down.
If you perform a reverse operation of the device longer than the set time, the number of fastened
screws of the last count down is to be counted up.
❼
<System>
This is used to set whether or not to use the buzzer sound for button operation and to use reverse
counting.
This has no effect on the buzzer sound during direct teaching or of <Fail> judgment.
❽
<Pulse detection>
This is used to set whether to detect an error of <Minimum pulse> or <Maximum pulse> in the
judgment of pass / fail.
❾
<Operation panel>
This is used to set whether to enable buttons on the operation panel.
❿
<Inactive time of torque-up>
This is used to set the time during which re-torque-up (confirming fastening, re-fastening, etc.) just
after torque-up is not to be detected as an error. During inactive times, the positive rotation data is
not sent.
⓫
Set command field
Enter a command.
⓬
[Send] button
The command is sent to the screwdriver.
⓭
[Clear] button
The log displayed in the log window is deleted.