[Monitor Operate] screen
12
/
52
■ Screen display items (numeric values)
Screen display
item
Description
The currently selected channel No. and pattern No. are displayed.
Rotation
(Rotation speed)
The motor rotation speed is displayed in units of rpm.
Motor trq
(Motor torque)
The motor torque is displayed in units of N.m.
Angle
(Rotation angle)
The current rotation angle is displayed in units of ° (degrees).
Hold time
(Holding time)
The holding time for the screw tightening operation is displayed in units of ms.
* See Chapter 15 "Holding time".
Error No.
The error No. of the current error is displayed. For details, see the "Error list" sections.
■ Screen display items (lamps)
Screen display item
Description
The start and finish status of the screw tightening operation is indicated.
[Strt] (Start): Lights up while screw tightening operation is being performed.
[Fin] (Finish): Lights up for 100 ms after screw tightening operation is complete.
The status of the screw tightening operation is indicated.
[Tmp] (Temporary tightening): Temporary tightening is being performed on the
screw.
[Full] (Full tightening): The temporary tightening operation has finished, and full
tightening is being performed.
[Add] (Additional tightening): The full tightening operation has finished, and
additional tightening is being performed.
The direction of the screw tightening operation is indicated.
[CW] (Clockwise): Screw tightening direction
[CCW] (Counterclockwise): Screw loosening direction
The status of the screw tightening operation is indicated.
[START OUT]: Lights up while screw tightening operation is being performed.
[FINISH OUT]: Lights up for 100 ms after screw tightening operation is complete.
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...