Operation parameters
20
/
52
■ Screen display items (buttons)
Screen display
button
Description
Save the currently configured parameters.
If parameters have already been saved, the data is overwritten.
When saving is complete, the [
特殊設定データ保存完了
] (Finished saving special setting
data) message window is displayed.
[Next]/[Prev]
Display the next or previous page of the [HIOS] setting screen.
Return to the [Edit] screen.
Set whether or not to use the torque-down filter.
Select [ON] to reduce the spring-back of the bit that occurs when the servo is turned OFF
after the pattern is complete.
The torque limit setting is changed before the servo turns OFF upon completion of the pattern
operation.
The torque limit setting changes based on the parameters specified for steps 1, 2, and 3, in
that order.
The wait time specifies the amount of time to wait before applying each change to the torque
limit setting.
* See Chapter 16.
8. Operation parameters
The tables in this chapter describe the parameter settings for each operation pattern, as well as the available setting ranges
for the [Edit] screen and [HIOS] screen settings.
■ Parameter settings for each operation pattern
Operation No.
Pattern 1
Pattern 2
Pattern 3
Pattern 4
Angle 1
(Rotation angle 1: °)
Specified rotation angle for temporary tightening
Angle 2
(Rotation angle 2: °)
Not used
Specified rotation angle for loosening
Angle 3
(Rotation angle 3: °)
Not used
Specified rotation
angle for additional
tightening
Not used
Specified rotation
angle for additional
tightening
Rotation 1
(Rotation speed 1: rpm)
Speed for temporary tightening
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Page 38: ... I O 38 52 Timing chart when emergency stop signal is input ...