Operation parameters
21
/
52
Rotation 2
(Rotation speed 2: rpm)
Speed for full
tightening
Speed for full
tightening and
additional tightening
Speed for full
tightening and
loosening
Speed for full
tightening,
loosening, and
additional tightening
Trq 1 (Torque 1: N.m)
Torque for temporary tightening
Trq 2 (Torque 2: N.m)
Torque for full tightening
Trq 3 (Torque 3: N.m)
Not used
Torque for additional
tightening
Not used
Torque for additional
tightening
Cycle TM (Cycle time: s)
Specified time for full set of operations of each pattern
Hold TM
(Holding time: ms)
Holding time after torque-up for full tightening and additional tightening
* See Chapter 15 "Holding time"
Torque allowance
(Torque judgment range:
±%)
Motor torque judgment range for full tightening and additional tightening
* See Chapter 16
Counter
(Torque judgment
counter)
Number of times to count full tightening and additional tightening torque judgment
* See Chapter 16
■ Parameter setting range for operation patterns
Parameter name
Description
Default value Min. value
Max.
value
Angle 1
(Rotation angle 1: °)
Specified rotation angle for temporary tightening
7200
1
59999
Angle 2
(Rotation angle 2: °)
Specified rotation angle for loosening
Pattern 3: 3
Pattern 4: 10
1
9999
Angle 3
(Rotation angle 3: °)
Specified rotation angle for additional tightening
60
30
9999
Rotation 1
(Rotation speed 1:
rpm)
Speed for temporary tightening
800
10
2800
Rotation 2
(Rotation speed 2:
rpm)
Speed for full tightening, loosening, and additional
tightening
100
10
2800
Trq 1
(Torque 1: N.m)
Torque for temporary tightening
0.300
0.300
1.300
Trq 2
(Torque 2: N.m)
Torque for full tightening
0.300
0.300
1.300
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Page 38: ... I O 38 52 Timing chart when emergency stop signal is input ...