Operation parameters
22
/
52
Trq 3
(Torque 3: N.m)
Torque for additional tightening
3.000
0.300
1.300
Cycle TM
(Cycle time: s)
Specified time for full set of operations of each pattern
30
5
100
Hold TM
(Holding time: ms)
Holding time after torque-up for full tightening and
additional tightening
* See Chapter 15 "Holding time"
150
50
500
Torque allowance
(Torque judgment
range: ±%)
Motor torque judgment range for full tightening and
additional tightening
5
1
99
Counter
Setting for number of times that normal motor torque value
is detected, for screw tightening judgment.
10
1
100
* The minimum value is 30° because the torque-down causes the bit to spring back when the servo turns OFF after full
tightening is complete.