Operation parameters
24
/
52
Reverse stand-by
(Wait time for angle judgment
in loosening operation)
This is the setting range of the required time,
calculated from the angle and speed of the
driver's loosening operation. The unit is ms.
100
0
999
Add angle range
(Additional tightening angle
judgment range)
This is the range for the angle judgment in
additional tightening.
The setting range is expressed in negative (-)
degrees.
10
0
999
Reverse angle range
(Loosening angle judgment
range)
This is the range for the angle judgment in
loosening.
The setting range is expressed in negative (-)
degrees.
10
0
999
Pattern 3, Reverse torque –
Full
(Torque for pattern 3
loosening operation -
Negative percentage of full
tightening torque)
This setting specifies the torque for the reverse
rotation, as negative torque relative to the full
tightening torque, to prevent excessive
looseness in the screw when the loosening
operation in pattern 3 is performed.
The unit is -%.
0
0
100
Torque down filter setting
1st step
(Torque-down filter setting -
Step 1 torque)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The torque
limit setting is changed based on the parameters
specified for steps 1, 2, and 3, in that order.
The unit is N.m. * See Chapter 16.
0.000
0.000
5.500
Torque down filter setting
2nd step
(Torque-down filter setting -
Step 2 torque)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The torque
limit setting is changed based on the parameters
specified for steps 1, 2, and 3, in that order.
The unit is N.m. * See Chapter 16.
0.000
0.000
5.500
Torque down filter setting
3rd step
(Torque-down filter setting -
Step 3 torque)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The torque
limit setting is changed based on the parameters
specified for steps 1, 2, and 3, in that order.
The unit is N.m. * See Chapter 16.
0.000
0.000
5.500
Torque down filter setting
Wait Time
(Torque-down filter setting -
Wait time)
This parameter is set to reduce the spring-back
of the bit that occurs when the servo is turned
OFF after the pattern is complete. The wait time
specifies the amount of time to wait before
applying each change to the torque limit setting.
The unit is msec. * See Chapter 16.
0
0
999
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Page 38: ... I O 38 52 Timing chart when emergency stop signal is input ...