■
I/O
31
/
52
■ Auto mode
Fig.8-3 Auto mode configuration
11. I/O
11.1 I/O allocation table
■ I/O
input signals
Signal
Signal name
Contact
Input
signal
Description
IN0
Start IN
A
OFF→ON
ON: Operation starts [Enabled in auto mode]
IN1
FOR/REV switching IN
A
Level
OFF: FOR (clockwise), ON: REV
(counterclockwise)
IN2
Auto/Manual switching IN
A
Level
OFF: Manual, ON: Auto
IN3
CH1 IN
A
OFF→ON
CH No. bit 0 [Enabled in auto mode]
IN4
CH2 IN
A
OFF→ON
CH No. bit 1 [Enabled in auto mode]
IN5
CH4 IN
A
OFF→ON
CH No. bit 2 [Enabled in auto mode]
IN6
CH8 IN
A
OFF→ON
CH No. bit 3 [Enabled in auto mode]
IN7
PTN1 IN
A
OFF→ON
PTN No. bit 0 [Enabled in auto mode]
IN8
PTN2 IN
A
OFF→ON
PTN No. bit 1 [Enabled in auto mode]
IN9
PTN4 IN
A
OFF→ON
PTN No. bit 2 [Enabled in auto mode]
IN10
Temporary/Full tightening
switching IN
A
OFF→ON
ON: Switch to full tightening operation, when
temporary tightening operation is being performed
IN11
-
-
-
-
IN12
Alarm reset IN
A
OFF→ON
ON: Reset alarm when alarm occurs
IN13
Emergency stop IN
A
OFF→ON
ON: Stop shaft rotation and generate an error
IN14
Torque judgment display clear
IN
A
OFF→ON
ON: Clear the torque judgment display on the touch
panel
IN15
Reverse IN
A
OFF→ON
ON: Start the reverse operation [Enabled in auto
mode]
Screwdriver
Touch panel
Start operation
External I/O switches
PTN
N
o
CH No
CW
/CCW
Au
to/
M
an
ua
l
St
art
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Page 38: ... I O 38 52 Timing chart when emergency stop signal is input ...