Message window
43
/
52
■
Message list
Message
Description
Data loaded
Finished loading the parameter settings.
Data saved
Finished saving the parameter settings.
特殊設定データ保存完了
(Finished saving special setting data)
Finished saving the parameters of special settings.
Torque OK
(Torque judgment OK)
The torque detection value is within the setting range.
* The torque is not displayed if the judgment count is set to 0.
Torque no good
Torque more than set
(Torque judgment NG -
Above motor torque setting)
The motor torque detection value is above the upper setting limit.
Torque no good
Torque less than set
(Torque judgment NG -
Below motor torque setting)
The motor torque detection value is below the lower setting limit.
No torque judgment
Displayed when screw is rotated to specified angle before torque-up is detected,
when performing additional tightening to specified angle.
Only the most recent motor torque value is displayed.
Additional tightening angle
When the additional tightening operation is performed in patterns 2 and 4, the
value specified for [Angle 3] (Rotation angle 3) on the touch panel display is used
to judge the angle of rotation after the torque-up of additional tightening.
Loosening angle
When the loosening operation is performed in patterns 3 and 4, the value
specified for [Angle 2] (Rotation angle 2) on the touch panel display is used to
judge the angle of rotation in the loosening operation.
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Page 38: ... I O 38 52 Timing chart when emergency stop signal is input ...