Holding time
46
/
52
15. Holding time
■ Holding time setting
The holding time setting range is from a minimum of 50 msec to a maximum of 500 msec.
Each screw tightening judgment takes several msec, so when the number of judgments is increased, the actual torque
holding time may become longer than the setting, depending on the holding time value that is specified. When increasing
the number of judgments, it is also necessary to specify a longer holding time.
When using chattering judgment for temporary tightening, a higher temporary tightening speed results in a longer torque
holding time.
When using chattering judgment for temporary tightening, a smaller difference between the temporary tightening torque
and full tightening torque results in a longer torque holding time.