Alarms
51
/
52
regeneration unit
TA8413 with 48 V
power supply
operation
error detection voltage"
(upper limit: 65 V)
72
Voltage Down Low drive
voltage
During operation
Insufficient power supply
capacity
Add regeneration
protection circuit to power
supply
Disconnection in drive
power supply line
When power is
turned ON
Disconnection in drive
power supply line
Check wiring
91
Flash Memory
Error
Non-volatile
memory read
error
When power is
turned ON
Failure of non-volatile
memory or CPU in
integrated circuit
Replace driver
92
Non-volatile
memory write
error
When writing the
parameters
Error list (motor driver errors)
Error
No.
Name
Description
Status
Cause
Solution
98
Hardware
Error
CPU error
Occurs while in
operation
Incorrect operation due to
noise
Install a noise filter
When power is
turned ON
Driver malfunction
Replace driver
99
Parameters
Error
Parameter
error
When writing the
parameters
Abnormal values when
writing the parameters to
non-volatile memory
(writing is not performed)
Check the values of the
parameter settings that
were changed
Summary of Contents for DCD-40L
Page 1: ...Current Controlled Screwdriver DCD 40L 115W Instruction Manual ET A070 19A HIOS Inc ...
Page 27: ... Operation timing charts 27 52 Pattern 2 ...
Page 28: ... Operation timing charts 28 52 Pattern 3 ...
Page 29: ... Operation timing charts 29 52 Pattern 4 ...
Page 37: ... I O 37 52 Timing chart for normal operations when torque judgment is NG ...
Page 38: ... I O 38 52 Timing chart when emergency stop signal is input ...